Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NO_BD_POWER

NO_BD_POWER

Description

Board not powered on. This alarm is generated when a board fails to start properly because the power module of the board does not apply sufficient power supplies to the board and as a result the CPLD is powered on but the CPU is not.

Attribute

Alarm Severity Alarm Type

Major

Equipment

Parameters

None

Impact on the System

The board fails to start properly.

Possible Causes

  • External power supplies cannot satisfy the power consumption requirements of the power supply module of the board.

  • The power supply module of the board is faulty.

Procedure

  1. Add external power supplies or replace the board.

Related Information

None