Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ODUk_PM_SSF

ODUk_PM_SSF

Description

The ODUk_PM_SSF alarm indicates that signals fail at the ODUk PM server layer.

k indicates the level of rate, its value is 0, 1, 2, 3, or flex.

Attribute

Alarm Severity Alarm Type

Warning

Communication alarm

Parameters

None

Impact on the System

Services carried on the channel that reports an ODUk_PM_SSF alarm are interrupted.

Possible Causes

  • An ODUk_PM_AIS or OTUk_TIM alarm is reported on the NE that reports an ODUk_PM_SSF alarm.

Procedure

  1. Check information about the ODUk_PM_SSF alarm on the NMS, and find the channel reporting the ODUk_PM_SSF alarm and the optical port housing the channel.
  2. Check for an ODUk_PM_AIS or OTUk_TIM alarm on the NE housing the optical port. If the NE reported any such alarms, clear these alarms.
  3. Check whether the ODUk_PM_SSF alarm is cleared. If the alarm persists, contact Huawei engineers to handle the alarm.