No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
E1DCN_64K_CONFLICT

E1DCN_64K_CONFLICT

Description

The E1DCN_64K_CONFLICT alarm indicates a timeslot resource conflict between the E1 DCN and 64 kbit/s services. The E1 DCN has priority over other features in using timeslots of 29 to 31. When the timeslots are used by other features, the E1DCN_64K_CONFLICT alarm is reported.

Attribute

Alarm Severity Alarm Type
Major Processing alarm

Parameters

None

Impact on the System

The 64 kbit/s services that have a timeslot resource conflict with the E1 DCN are interrupted. Other 64 kbit/s services are not affected.

Possible Causes

Cause: The E1 DCN needs to use timeslots of 29 to 31, but these slots are used by other features. Other features include:

  • E1 SNCP
  • 64 kbit/s service cross-connection
  • 8 kbit/s service cross-connection
  • Multiplexer group
NOTE:

This alarm is also reported when the timeslots of 29 to 31 of the E1 SNCP sink board are used.

Procedure

  1. Cause: The E1 DCN needs to use timeslots of 29 to 31, but these slots are used by other features.
    1. Query the alarm on the NMS. Determine the board that reports the alarm, and determine the number of the path that reports the alarm based on alarm parameters.
    2. Configure the feature (E1 SNCP, 64 kbit/s service cross-connection, or other feature) that uses the timeslots of 29 to 31 in other timeslots.
    3. Check whether the alarm is cleared. If the alarm persists, contact Huawei technical support engineers to handle the alarm.

Related Information

None