Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MULTI_RPL_OWNER

MULTI_RPL_OWNER

Description

The MULTI_RPL_OWNER is an alarm indicating that an Ethernet ring network contains more than one RPL_OWNER node.

Attribute

Alarm Severity Alarm Type
Minor Operation alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning
Parameter 1, Parameter 2 Indicate the Ethernet ring protection ERPS instance ID.

Impact on the System

All the nodes on an Ethernet ring network lose connectivity. If the Ethernet ring network is configured with services, services are interrupted.

Possible Causes

Possible cause of this alarm is as follows:

The Ethernet ring network contains more than one RPL_OWNER node.

Procedure

  1. Check whether the Ethernet ring network contains more than one RPL_OWNER node.

    If... Then...

    The Ethernet ring network contains more than one RPL_OWNER node

    Reconfigure the ERPS protection. Ensure that all nodes on the Ethernet ring network are configured with ERPS protection and the Ethernet ring network contains only one RPL_OWNER node.

    The Ethernet ring network contains only one RPL_OWNER node

    Contact Huawei technical support engineers for handling the alarm.