Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
AUPJCHIGH

AUPJCHIGH

Description

The AUPJCHIGH event indicates the count of positive AU pointer justifications.

Attribute

Performance Event ID Performance Event Type

0x2a

SDH performance event

Impact on the System

A small pointer justification does not affect the services, whereas a large pointer justification causes bit errors in the services. If a large pointer justification occurs, identify the causes and rectify the fault immediately. These operations help to prevent alarms and to ensure signal transmission quality.

Possible Causes

External causes:

  • A fiber is incorrectly connected, resulting in a clock loop of the two NEs.

  • If the NEs trace the external clock, check the quality of the external clock.

Human factors:

  • The configuration of the clock source is incorrect. There are two clock sources in one network.

  • The configuration of the clock source tracing priority is incorrect. The clocks of the two NEs trace each other.

Equipment problems:

  • The line board is faulty. As a result, the clock is of poor quality.

  • The clock unit is faulty. As a result, the clock source is of poor quality, or the traced clock source cannot be locked.

Related Alarms

Alarm Name Correlation

MSAD_CROSSTR

Multiplex section adaptation performance threshold crossing alarm

RS_CROSSTR

Regenerator section performance threshold crossing alarm

MS_CROSSTR

Multiplex section performance threshold crossing alarm

Procedure

  1. For non-network-wide pointer justifications, check whether fibers are correctly connected.
  2. If the NEs trace the external clock, check the quality of the external clock.
  3. Verify that the configuration is correct.

    NOTE:
    Check the configuration items, such as clock ID, SSM protocol, and clock tracing priority.

  4. Analyze pointer justification performance events, and locate the fault by changing the position of the clock source and clock tracing direction. Replace the faulty line board or clock unit.

Related Information