Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BIOS_STATUS

BIOS_STATUS

Description

The BIOS_STATUS alarm indicates the BIOS state. By default, if loading board software fails for five consecutive times within 780 seconds, the board enters the BIOS state and the BIOS_STATUS alarm is reported.

Attribute

Alarm Severity Alarm Type

Major

Environment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

Indicates the slot number of the board in the BIOS state.

Impact on the System

Services are interrupted.

Possible Causes

Possible causes of this alarm are as follows:

  • The software is lost.
  • Incorrect software is loaded.
  • Writing or reading the software becomes abnormal.
  • The board hardware is faulty.

Procedure

  1. View the BIOS_STATUS alarm on the U2000 to determine the board that reports the BIOS_STATUS alarm according to Parameter 1.
  2. Perform warm reset on the board. Then, check whether the BIOS_STATUS alarm is cleared.

    If... Then...

    The alarm persists

    Perform a cold reset on the board. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.

    The alarm is cleared

    No further action is required.

  3. Contact Huawei technical support engineers to handle the alarm.

Related Information