OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
J0_MM

J0_MM

Description

The J0_MM alarm indicates inconsistent regenerator section trace identifiers (J0 bytes).

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

Indicates the optical port number.

Impact on the System

None.

Possible Causes

The possible cause of this alarm is as follows:

  • The regenerator section trace identifier (J0 byte) transmitted by the opposite end is not the same as the regenerator section trace identifier (J0 byte) that the local end is supposed to receive.

Procedure

  1. On the U2000, check whether the regenerator section trace identifier (J0 byte) transmitted by the opposite end is the same as the regenerator section trace identifier (J0 byte) that the local end is supposed to receive. Ensure that they are the same.
  2. Check on the U2000 whether the J0_MM alarm is cleared.

    If... Then...
    If this alarm is cleared No further action is required.
    If this alarm persists Go to the next step.

  3. If the alarm persists, perform a self-loop with optical fibers for the optical ports on the line boards at the two end. Replace the board that still reports the J0_MM alarm.

Related Information

None.