Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ERPS_IN_PROTECTION

ERPS_IN_PROTECTION

Description

ERPS_IN_PROTECTION indicates that EPRS ring is in protection mode.

Attribute

Alarm Severity Alarm Type

Minor

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1, Parameter 2

ERPS ID.

Parameter 3

DIR, indicating whether the faulty node is in the east or west direction of the ERPS RPL-OWNER node.
  • 0x00: west
  • 0x01: east

Parameter 4, Parameter 5, Parameter 6, Parameter 7, Parameter 8, Parameter 9

NODE ID, indicating the MAC address of the faulty node.

Impact on the System

At least one node on the ring is unreachable. Services (if any) on this node may be interrupted.

Possible Causes

Possible causes of the ERPS_IN_PROTECTION alarm are as follows:

  • Cause 1: This alarm is reported when EPRS switching is triggered by a fault on the ERPS ring.

Procedure

  1. Locate the faulty node on the ERPS ring based on the alarm parameters.
  2. Locate the ERPS blocked port on the faulty node.
  3. Rectify the fault.

Related Information

None.