Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PW_APS_OUTAGE

PW_APS_OUTAGE

Description

The PW_APS_OUTAGE alarm indicates that a pw APS protection group fails. This alarm is reported when both the protection and working pws in a pw APS protection group fail, and is cleared when either of the protection or working pw recovers.

Attribute

Alarm Severity Alarm Type

Major

Service alarm

Parameters

None

Impact on the System

The pw APS group fails and services in the group are interrupted.

Possible Causes

Possible causes of this alarm are as follows:

  • Cause 1: Ports carrying the working and protection pws are not enabled.
  • Cause 2: Fibers connections are faulty.
  • Cause 3: Alarms occur on both the working and protection pws.

Procedure

  1. Query the status of the pw APS protection group on the U2000 and identify the working and protection pws.
  2. Cause 1: Ports carrying the working and protection pws are not enabled.
    1. Check whether ports carrying the working and protection pws are enabled. If they are not enabled, enable them.
    2. Check whether the alarm is cleared. If the alarm persists, go to 3.
  3. Cause 2: Fibers connections are faulty.
    1. Replace the faulty fibers or connect the fibers correctly.
    2. Check whether the alarm is cleared. If the alarm persists, go to 4.
  4. Cause 3: Alarms occur on both the working and protection pws.
    1. Check for alarms, such as MPLS_PW_LOCV, on the working and protection pws. If such an alarm occurs, clear the alarm first.
    2. Check whether the PW_APS_OUTAGE alarm is cleared. If the alarm persists, contact Huawei technical support personnel to handle the alarm.