Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MCLAG_CFG_MISMATCH

MCLAG_CFG_MISMATCH

Description

The MCLAG_CFG_MISMATCH alarm indicates that MC-LAG configurations at two ends are inconsistent.

Attribute

Alarm Severity Alarm Type

Major

Communication alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1, Parameter 2

Indicate the mismatch type.

  • 0x01: The LAG IDs at two ends are different.
  • 0x02: The LAG aggregation types at two ends are different.
  • 0x04: The MC-LAG load-sharing modes at two ends are different.
  • 0x08: The MC-LAG revertive modes at two ends are different.

Impact on the System

Negotiation of MC-LAG configurations fails and services may be unavailable.

Possible Causes

The possible causes of the MCLAG_CFG_MISMATCH alarm are as follows:

  • Cause 1: The LAG IDs at two ends are different.
  • Cause 2: The LAG aggregation types at two ends are different.
  • Cause 3: The MC-LAG load-sharing modes at two ends are different.
  • Cause 4: The MC-LAG revertive modes at two ends are different.

Procedure

  1. Cause 1: The LAG IDs at two ends are different.

    Cause 2: The LAG aggregation types at two ends are different.

    Cause 3: The MC-LAG load-sharing modes at two ends are different.

    Cause 4: The MC-LAG revertive modes at two ends are different.

    1. Check whether the MC-LAG parameters (such as LAG ID, LAG aggregation type, LAG load-sharing mode, and LAG revertive mode) at the two ends are set to the same. If the MC-LAG parameters at the two ends are different, change them to the same. Then, check whether the alarm is cleared.
    2. If the alarm persists, contact Huawei technical support engineers for handling the alarm.