OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TD

TD

Description

The TD alarm indicates laser transmit performance deteriorates. This alarm is reported if the bias current of the laser is higher than A, which is 1.2 times greater than the initial bias current value, and lower than B, which is 1.5 times greater than the initial value.

Attribute

Alarm Severity Alarm Type

Critical

Equipment alarm

Parameters

None

Impact on the System

The laser cannot work properly and bit errors occur. Services may be interrupted.

Possible Causes

Cause: The laser is aged.

Procedure

  • Cause: The laser is aged.
    1. Check whether the board supports pluggable optical modules.

      If...

      Then...

      The board supports pluggable optical modules

      Replace pluggable optical modules. For details, see Replacing the Optical Module. If the alarm persists, replace the faulty board.

      The board does not support pluggable optical modules

      Reset the board. For details, see Resetting Boards.

      If the alarm persists, replace the faulty board.

    2. If the alarm persists, contact Huawei technical support personnel to handle the alarm.

Related Information

In a cooled optical module that adopts automatic level control (ALC), its laser ages after working for a long time, resulting in reduced emission efficiency. To ensure constant output optical power, the laser bias current, an indicator of laser aging degree, should be increased.

Translation