No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PCM_DATA_CONFLICT

PCM_DATA_CONFLICT

Description

The PCM_DATA_CONFLICT alarm indicates a data conflict of multiplexer group members. This alarm is reported when a multiplexer group receives multiple channels of valid data simultaneously and a data conflict occurs.

Attribute

Alarm Severity Alarm Type
Major Processing alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning
Parameter 1

This parameter is meaningless. It has a fixed value of 0x01.

Parameter 2

Indicates the timeslot ID.

Parameter 3

Indicates the path numbers.

Impact on the System

Services of the multiplexer group are interrupted.

Possible Causes

Cause: The multiplexer group receives multiple channels of valid data simultaneously, which causes a data conflict.

As shown in Figure 4-31, if service signals from both Slave 1 and Slave 2 to the Master are valid, a data conflict of the multiplexer group members occurs on NE1. NE1's ports that receive services from Slave 1 and Slave 2 report PCM_DATA_CONFLICT alarms.

Figure 4-31  PCM_DATA_CONFLICT alarm generation (Data-P2MP)

Procedure

  1. Cause: The multiplexer group receives multiple channels of valid data simultaneously, which causes a data conflict.
    1. Query the alarm on the NMS. Determine the number of the path where the data conflict occurs in the multiplexer group based on alarm parameters.
    2. Ensure that the PCM devices connected to the path do not transmit valid data simultaneously.
    3. Check whether the alarm is cleared. If the alarm persists, contact Huawei technical support engineers to handle the alarm.

Related Information

None