Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FXO_POWER_FAULT

FXO_POWER_FAULT

Description

The FXO_POWER_FAULT alarm indicates the absence of a feeding current on a foreign exchange office (FXO) port. An FXO port on an NE reports an FXO_POWER_FAULT alarm when failing to receive a feeding signal.

As shown in Figure 4-4, an FXO port on NE 2 connects to a private branch exchange (PBX), which connects to plain old telephone service (POTS) telephone sets. An FXO port on NE 2 reports an FXO_POWER_FAULT alarm when failing to receive a feeding signal from NE 1.

Figure 4-4  FXO_POWER_FAULT reporting

Attribute

Alarm Severity Alarm Type

Major

Communication alarm

Parameters

None

Impact on the System

Calls set up on a PBX that connects to an NE reporting an FXO_POWER_FAULT alarm are interrupted.

Possible Causes

Possible causes of this alarm are as follows:

  • Cause 1: The transmission line between the NE reporting an FXO_POWER_FAULT alarm and the equipment supplying a feeding current to the NE is malfunctioning.
  • Cause 2: The received current exceeds the threshold allowed by FXO ports.
  • Cause 3: The board reporting an FXO_POWER_FAULT alarm is faulty.

Procedure

  1. Cause 1: The transmission line between the NE reporting an FXO_POWER_FAULT alarm and the equipment supplying a feeding current to the NE is malfunctioning.
    1. Check whether the transmission line is cut, is damaged, or is malfunctioning. If a fault is found, replace the transmission line.
    2. Check whether the alarm is cleared. If the alarm persists, go to 2.
  2. Cause 2: The received current exceeds the threshold allowed by FXO ports.
    1. Change Min. Current (mA) or Max. Current(mA) of FXO ports. For details, see Configuring a PCM Port in the Configuration Guide (SDH Transport Domain).
    2. Check whether the alarm is cleared. If the alarm persists, go to 3.
  3. Cause 3: The board reporting an FXO_POWER_FAULT alarm is faulty.
    1. Replace the board.
    2. Check whether the alarm is cleared. If the alarm persists, contact Huawei engineers to handle the alarm.

Related Information

For information about working principles of telephone lines, see Embedded PCM in the Feature Description.

Translation
Download
Updated: 2019-01-21

Document ID: EDOC1100020975

Views: 76578

Downloads: 138

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next