Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List C

Alarm List C

This section used a table to list the alarms starting with C.

Name Description Severity Applicable Equipment
C2_VCAIS Indicates a C2 byte alarm. Minor OptiX OSN 580
C3794_SLOTNUM_ERR The actually received timeslot bandwidth of C37.94 services does not match the configured timeslot bandwidth on the NMS. Major OptiX OSN 550/580
C3794_RDI Indicates that data reception of C37.94 services at the remote end fails. Minor OptiX OSN 550/580
C3794_AIS Indicates that C37.94 services are faulty. Minor OptiX OSN 550/580
CES_ACR_LOCK_ABN Indicates that the CES ACR clock is locked abnormally. Minor OptiX OSN 550/500
CES_APS_INDI Indicates that the configured packet MSP for a CES service is in the switching state. Major OptiX OSN 550/500
CES_APS_MANUAL_STOP Indicates that the packet linear MSP protocol is stopped manually. Minor OptiX OSN 550/500
CES_JTROVR_EXC Indicates that the number of jitter buffer overflows exceeds the specified threshold value. Major OptiX OSN 550/500
CES_JTRUDR_EXC Indicates that the number of jitter buffer underflows exceeds the specified threshold value. Major OptiX OSN 550/500
CES_K1_K2_M Indicates the mismatch between the K1 byte and the K2 byte. Minor OptiX OSN 550/500
CES_K2_M Indicates that a mismatched K2 byte of packet MSP is detected. Minor OptiX OSN 550/500
CES_LOSPKT_EXC Indicates that the number of lost CES service packets exceeds the specified threshold in a certain period. Major OptiX OSN 550/500
CES_MALPKT_EXC Indicates that the number of deformed CES service packets exceeds the specified threshold in a certain period. Major OptiX OSN 550/500
CES_MISORDERPKT_EXC Indicates that the number of lost out-of-order CES service packets exceeds the specified threshold in a certain period. Major OptiX OSN 550/500
CES_RDI Indicates a failure in remote CES services. Minor OptiX OSN 550/500
CES_STRAYPKT_EXC Indicates that the number of error CES service packets exceeds the specified threshold in a certain period. Major OptiX OSN 550/500
CESPW_OPPOSITE_ACFAULT Indicates a defect in an attachment circuit. Major OptiX OSN 550/500
CESPW_OPPOSITE_RAI Indicates an alarm on the NE at the opposite end. Major OptiX OSN 550/500
CFCARD_FAILED Indicates that operations on the CF card fail. Major OptiX OSN 550/500
CFCARD_FULL Indicates that the capacity of the CF card is used up. Major OptiX OSN 550/500
CFCARD_OFFLINE Indicates that the CF card is offline. Major OptiX OSN 550/500
CFG_DATACHECK_FAIL Indicates an error in routine database check. Major OptiX OSN 550/500/580
CFG_DATASAVE_FAIL Indicates a data save failure. Major OptiX OSN 550/500/580
CHCS Indicates that a correctable bit error occurs in the cell header. Minor OptiX OSN 550/500
CHIP_ABN Indicates a failure in the voltage chip or temperature chip. Minor OptiX OSN 550
CLK_LOCK_FAIL Indicates a failure to lock the clock. Major OptiX OSN 550/500/580
CLK_NO_TRACE_MODE Indicates that the clock changes to a non-tracing running mode. Minor OptiX OSN 550/500/580
COM_EXTECC_FULL Indicates the excessive number of TCP connections between the NEs running the automatic extended ECC communication protocol. Major OptiX OSN 550/500/580
COMMUN_FAIL Indicates an inter-board communication failure. Major OptiX OSN 550/500/580
CPU_BUSY Indicates that the CPU utilization is excessively high. Major OptiX OSN 550/500
CRC4_ERR_OVER Indicates that the errors of CRC4 check for the E1 services cross the threshold. Minor OptiX OSN 550/580
CTS Indicates that the data terminal equipment (DTE, namely, the DDN service board) at the local station has detected the abnormal Clear To Send status. Major OptiX OSN 550/580