Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ETHOAM_RMT_SD

ETHOAM_RMT_SD

Description

The ETHOAM_RMT_SD is an alarm indicating the remote performance degradation of the point-to-point Ethernet OAM function. When the alarm is reported, a port with the OAM function enabled receives a link event message from the opposite end, indicating that the Ethernet performance is degraded at the remote end.

Attribute

Alarm Severity Alarm Type

Minor

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

Indicates the port number.

Parameter 2, Parameter 3

Parameter 2 is always 0x00, and Parameter 3 is always 0x01. These parameters are meaningless.

Parameter 4

Indicates the event type.

  • 0x01: errored frame event
  • 0x02: errored frame period event
  • 0x03: errored frame second event

Impact on the System

The alarm is generated when the system runs the IEEE 802.3ah protocol. IEEE 802.3ah is a link management protocol and is irrelevant to services. When the alarm is reported, the number of errored frames crosses the threshold at the receive direction of the local port. The service performance is degraded.

Possible Causes

The possible causes of the ETHOAM_RMT_SD alarm are as follows:

  • The port with the OAM protocol enabled receives the link event message from the opposite end.

Procedure

  1. Improve the link performance at the opposite end so that the opposite end does not send a link event message to the local end any longer. Then, the ETHOAM_RMT_SD alarm at the local end is cleared automatically.
  2. Modify the value of the link performance monitoring threshold at the opposite end. Then, the ETHOAM_RMT_SD alarm at the local end is cleared.
  3. Disable the link event function at the opposite end. Then, the ETHOAM_RMT_SD alarm at the local end is cleared.

Related Information