Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ODUk_TCMn_DEG

ODUk_TCMn_DEG

Description

ODUk TCMn signal being degraded. This alarm is generated if signal degradation occurs or the bit error count exceeds the threshold when the error detection is in burst mode.

  • k indicates the level of rate, its value is 0, 1, or 2.
  • n indicates the level of TCM, its value ranges from 1 to 6.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None

Impact on the System

If the alarm is generated, the services at the optical interface generate bit errors, which make the service signals unavailable.

Possible Causes

  • The optical interface that reports the alarm is faulty.

  • The optical interface at the peer end is faulty.

  • The fiber of the transmission line is abnormal.

Procedure

  1. On the NMS, browse alarms of the entire network to determine the slot ID, interface ID, and channel ID of the board that generates this alarm.
  2. Locate the point that first generates the ODUk_TCMn_DEG alarm according to the service route.
  3. Check whether the input optical power of the place where the alarm is first generated is within the permitted range on the NMS. If it is not, handle the alarm according to the handling procedures of the IN_PWR_HIGH and IN_PWR_LOW alarms.
  4. If the alarm persists, check whether the fiber meets the following requirements:

    • The bending radius is not less than 6 cm.
    • The optical interface connector is well inserted.
    • The fiber connector is clean.
    • The cable is intact.

    If the preceding requirements are not met, clean the fiber connector or replace the fiber. For details, see Cleaning the Optical Fiber Connector.

  5. If the alarm persists, the optical interface on the board at the local end may be faulty. Replace the pluggable optical module or the faulty board.
  6. If the alarm persists, the optical interface on the universal line board at the peer end may be faulty. Replace the pluggable optical module on the board or the faulty OTU board.
  7. Check whether the alarm is cleared. If the alarm persists, contact Huawei engineers to handle the alarm.