Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
APS_MANUAL_STOP

APS_MANUAL_STOP

Description

The APS_MANUAL_STOP alarm indicates that the automatic multiplex section protection (MSP) switching protocol is stopped manually.

Attribute

Alarm Severity Alarm Type

Minor

Processing alarm

Parameters

None.

Impact on the System

Protected services lose protection from MSP switching.

Possible Causes

The possible cause of this alarm is as follows:

The command for stopping the protection group protocol controller is manually issued.

Procedure

  1. Start the protection group protocol controller on the U2000. Then, check whether the alarm is cleared.

    If... Then...

    The alarm is cleared

    No further action is required.

    The alarm persists

    Contact Huawei technical support engineers to handle the alarm.

Related Information