OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TEM_LA

TEM_LA

Description

The TEM_LA alarm indicates that the temperature of the laser exceeds the lower threshold.

Attribute

Alarm Severity Alarm Type

Major

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

Indicates the port number.

Impact on the System

When the TEM_LA alarm is reported, the laser is faulty. Consequently, the transmit circuit will be faulty and bit errors will occur, resulting in service interruptions.

Possible Causes

Possible causes of the TEM_LA alarm are as follows:

  • The ambient temperature of the board is low.
  • The optical module is faulty.
  • The line board is faulty.

Procedure

  1. Check the temperature of the NE subrack.

    If... Then...

    The temperature of the NE subrack is low

    Increase the ambient temperature to the allowed range. Check whether the alarm is cleared. If the alarm persists, go to the next step.

    The temperature of the NE subrack is normal

    Go to the next step.

  2. Check the alarmed line board and replace the optical module. Check whether the alarm is cleared.

    If... Then...

    The alarm persists

    Go to the next step.

    The alarm is cleared

    No further action is required.

  3. Replace the line board.

Related Information

None.