Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LP_SIZE_ERR

LP_SIZE_ERR

Description

The LP_SIZE_ERR alarm indicates incorrect TU specifications. This alarm is generated when the mapping structure of the TU services (lower order services) received by a board is inconsistent with that specified for the board.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None.

Impact on the System

The lower order services are interrupted.

Possible Causes

The possible cause of this alarm is as follows:

  • The mapping structure of the lower order services is incorrectly configured.

Procedure

  1. View the LP_SIZE_ERR alarm on the U2000 to determine the ID of the path where the LP_SIZE_ERR alarm is generated.
  2. Re-configure the mapping structure of the lower order services transmitted over the path. Then, the LP_SIZE_ERR alarm is automatically cleared.

Related Information

None.