Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LSR_WILL_DIE

LSR_WILL_DIE

Description

The LSR_WILL_DIE alarm indicates that the life of the laser on the board will end.

Attribute

Alarm Severity Alarm Type

Critical

Equipment alarm

Parameters

None.

Impact on the System

If the life of the laser ends, the board cannot transmit and receive services correctly. The laser must be replaced as soon as possible.

If the laser is not replaced in a timely manner, services will be interrupted.

Possible Causes

The possible cause of this alarm is as follows:

The laser is deteriorating, which causes excessively high bias current.

Procedure

  1. Replace the laser. Then, check whether the alarm is cleared.

    If... Then...

    The alarm persists

    Replace the board that reports the alarm.

    The alarm is cleared

    No further action is required.