Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List S

Alarm List S

This section used a table to list the alarms starting with S.

Name Description Severity Applicable Equipment
S1_SYN_CHANGE Indicates that the clock reference source of the clock board is switched in the S1 byte mode. Major OptiX OSN 550/500/580
SEC_RADIUS_FAIL Indicates that the number of consecutive RADIUS authentication failures is too great. Major OptiX OSN 550/500/580
SECU_ALM Indicates that the SCC reports an illegal login. Major OptiX OSN 550/500/580
SERVICE_CAPACITY_EXCEED_LICENSE Indicates that the capacity of the services configured for a equipment exceeds the limit defined by the license. Major OptiX OSN 580
SERVICE_TYPE_EXCEED_LICENSE Indicates that the service type exceeds the license limit. Major OptiX OSN 580
SLAVE_WORKING Indicates that the protection board is working. Warning OptiX OSN 550/580
SOFTWARE_UNCOMMIT Indicates that the board software is unauthorized. Major OptiX OSN 550/500
SRV_LOOP_LD Indicates that an Ethernet service loop occurs. Major OptiX OSN 550/500/580
SRV_SHUTDOWN_LD Indicates that the Ethernet private service is stopped. Major OptiX OSN 550/500/580
SSL_CERT_DAMAGED Indicates that the Secure Sockets Layer (SSL) certificate file is damaged. Critical OptiX OSN 550/500/580
SSL_CERT_NOENC Indicates that the Secure Sockets Layer (SSL) certificate file is not encrypted. Major OptiX OSN 550/500/580
SSL_CERT_TO_EXPIRE Indicates that the Secure Sockets Layer (SSL) certificate file is about to expire. Critical OptiX OSN 550/500/580
SSM_LOS Indicates that the SSM quality information fails to be received. Minor OptiX OSN 580
SSM_QL_FAILED Indicates that the received SSM quality is worse than the threshold. Minor OptiX OSN 580
STORM_CUR_QUENUM_OVER Indicates that the number of current alarms on the NE reaches the value that is equal to the maximum number of alarms supported by an alarm queue minus one. Minor OptiX OSN 550/500/580
SUBNET_RT_CONFLICT Indicates that subnets conflict on a data communication network (DCN). Minor OptiX OSN 550/500/580
SUBRATE_PROTOCOL_MM Indicates a rate mismatch of a sub-rate protocol serial port. Major OptiX OSN 550/580
SUM_INPWR_HI Indicates that the input optical power is excessively high. Major OptiX OSN 550/580
SUM_INPWR_LOW Indicates that the total input optical power is excessively low. Major OptiX OSN 550/580
SWDL_ACTIVATED_TIMEOUT Indicates that during software package loading, the NE does not perform the commit operation in a certain time after the board is activated. Critical OptiX OSN 550/500/580
SWDL_AUTOMATCH_INH Indicates that the automatic match function is disabled. Minor OptiX OSN 550/500/580
SWDL_BD_EXCLUDE Indicates that a board is excluded from software download during software package downloading. Major OptiX OSN 580
SWDL_BD_MATCH_FAIL Indicates a board software matching failure. Minor OptiX OSN 550/500/580
SWDL_BD_WEAKMATCH Indicates weak mapping during an upgrade by means of package loading. Minor OptiX OSN 580
SWDL_CHGMNG_NOMATCH Indicates that the NE software does not match the board software. Critical OptiX OSN 550/500/580
SWDL_COMMIT_FAIL Indicates that the commission operation on the NE fails. Minor OptiX OSN 550/500/580
SWDL_INPROCESS Indicates that the NE is loading the software package. Warning OptiX OSN 550/500/580
SWDL_NEPKGCHECK Indicates that software package files are lost. Critical OptiX OSN 550/500/580
SWDL_PKG_NOBDSOFT Indicates that certain board software is missing from the software package. Minor OptiX OSN 550/500/580
SWDL_PKGVER_MM Indicates that the software package version is inconsistent with the software version specified in the software package. Minor OptiX OSN 550/500/580
SWDL_ROLLBACK_FAIL Indicates that some board rollback fails when the NE performs rollback. Minor OptiX OSN 550/500/580
SYN_BAD Indicates that the current synchronization clock source of the clock board is degraded. Minor OptiX OSN 550/500/580
SYNC_C_LOS Indicates that the clock source of the clock board that is set in the clock source priority table is lost. Warning OptiX OSN 550/500/580
SYNC_CONFIG_ERR Indicates that the clock source configurations of an NE are incorrect. Minor OptiX OSN 580
SYNC_DISABLE Indicates that the automatic synchronization of SCC boards is disabled. Minor OptiX OSN 550/580
SYNC_F_M_SWITCH Indicates the forced or manual switching state of a clock source. Warning OptiX OSN 580
SYNC_FAIL Indicates that the batch backup of the databases of the active and standby SCC boards fails. Minor OptiX OSN 550/580
SYNC_LOCKOFF Indicates that the clock source in the priority list is locked. Warning OptiX OSN 580
SYSLOG_COMM_FAIL Indicates that communication between the NE and the Syslog server fails. Major OptiX OSN 550/500/580