Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting Network-Wide Performance Monitoring

Setting Network-Wide Performance Monitoring

This section describes how to enable and disable the performance monitoring function on the U2000. The performance parameters are used to monitor the equipment, monitor the running status of the services, and analyze the network.

Prerequisites

The U2000 server and U2000 client must be started.

Tools, Equipment and Materials

U2000

Precautions

In normal cases, all the performance parameters are set to the default values. You only need to enable the performance monitoring function. You can also set the performance parameters depending on the actual situations.

Procedure

  1. Log in to the U2000 client. Choose Configuration > NE Batch Configuration > NE Time Synchronization from the Main Menu.
  2. Select the NEs from the Object Tree and click .
  3. Set Synchronous Mode of each NE to NM, and click Apply. A dialog box is displayed indicating that the operation is successful. Click Close.



  4. Select all the NEs and right-click to select Synchronize with NM Time. Click Yes in the displayed dialog box.
  5. A dialog box is displayed indicating that synchronization is successful. Click Close.
  6. Choose Performance > NE Performance Monitor Time from the Main Menu.
  7. Select an NE and click .
  8. Select one or more NEs and set the 15-minute and 24-hour performance monitoring parameters according to the requirements.

    NOTE:
    • The start time must be later than the current time of the U2000 and the end time must be later than the start time.
    • If the end time is not set, it indicates that performance monitoring starts from the start time and does not stop.


  9. Click Apply. A dialog box is displayed indicating that the operation is successful. Click Close.