Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuration Process

Configuration Process

This topic describes how to configure the F1 data service.

Prerequisites

Procedure

  1. To configure the F1 data service of NE1, do as follows:
    1. Select NE1 in the NE Explorer, and then choose Configuration > Orderwire from the Function Tree.
    2. Click the F1 Data Port tab and set the parameters as listed in the following table. Then, click Apply.

      Parameter Value in This Example Description
      Data Channel 1 F1 The F1 data service is added or dropped through F1 of Data Channel 1.
      Data Channel 2 1-SL1D-1 The F1 data service passes through 1-SL1D-1 of Data Channel 2.

  2. To configure the F1 data service of NE2, do as follows:

    Refer to Step 1 and configure the F1 data service of NE2.
    Parameter Value in This Example Description
    Data Channel 1 2-SL1D-1 The F1 data service passes through 2-SL1D-1 of Data Channel 1.
    Data Channel 2 1-SL1D-1 The F1 data service passes through 1-SL1D-1 of Data Channel 2.

  3. To configure the F1 data service of NE3, do as follows:

    Refer to Step 1 and configure the F1 data service of NE3.
    Parameter Value in This Example Description
    Data Channel 1 2-SL1D-1 The F1 data service passes through 2-SL1D-1 of Data Channel 1.
    Data Channel 2 F1 The F1 data service is added or dropped through F1 of Data Channel 2.

  4. See Setting Network-Wide Performance Monitoring and enable the performance monitoring function of the NEs.
  5. Back up the configuration data of the NEs. For details, see Backing Up the NE Data to the System Control Board.