Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the NE Data

Configuring the NE Data

After an NE is created, you need to configure the data of the NE on the U2000. Otherwise, the U2000 still cannot manage the NE.

Configuring the NE Data Manually

By configuring NE data manually, you can configure the slot layout information of an NE.

Prerequisites

  • The NE must be created successfully.
  • You are an NM user with Operator Group rights or higher.

Procedure

  1. Double-click the unconfigured NE on the Main Topology. Then, the NE Configuration Wizard dialog box is displayed.

  2. Select Manual Configuration and click Next. Then, the Confirm dialog box is displayed, indicating that manual configuration clears the data on the NE.
  3. Click OK. Then, the Confirm dialog box is displayed, indicating that manual configuration interrupts the service on the NE.
  4. Click OK. Then, the Set NE Attribute dialog box is displayed.
  5. Set NE Name, Equipment Type, NE Remarks, and Shelf Type and then click Next. The NE slot layout window is displayed.
  6. Optional: Click Query Logical Information to query the logical boards of the NE.
  7. Optional: Click Query Physical Information to query the physical boards of the NE.

    NOTE:
    The Query Logical Information and Query Physical Information operations cannot be performed for a preconfigured NE.

  8. Right-click the slot to which you need to add a board. Click Next. Then, the Send Configuration window is displayed.
  9. Select Verify and Run according to the requirements and click Finish.

    NOTE:
    Verification is to run the verification command. Click Finish to deliver the configuration data to the NE, thereby completing the basic configuration of the NEs. After the successful verification, the NEs start to work normally.

Follow-up Procedure

Configure logical ports for boards.

  1. Double-click the configured NE in the Main Topology.

    The NE Panel dialog box is displayed.

  2. Select a board and then a port for which a logical port is to be configured. Right-click the port and choose Add Port from the shortcut menu.

    The Add Port dialog box is displayed.

  3. Configure a logical port according to the board conditions. Then, click OK.

Replicating the NE Data

You can directly replicate the data of an NE that is of the same NE type and NE version to the newly created NE.

Prerequisites

  • The NE must be created successfully.
  • The NE type and NE version of the source NE must be the same as the NE type and NE version of the newly created NE.
  • You are an NM user with Operator Group rights or higher.

Procedure

  1. Double-click the unconfigured NE on the Main Topology. Then, the NE Configuration Wizard dialog box is displayed.
  2. Select Copy NE Data and click Next. Then, the NE Replication dialog box is displayed.
  3. Select the NE from the drop-down list and click Start. Then, the Confirm dialog box is displayed, indicating that the replication operation copies all the data of the source NE.

    NOTE:

    After the NE data is replicated, only the data on the U2000 is changed, but the data on the equipment is not changed.

  4. Click OK. Then, the Confirm dialog box is displayed, indicating that the replication operation results in the loss of the original data of the NE to which the data is replicated.
  5. Click OK to start the replication.
  6. Wait for several seconds. Then, in the Result dialog box indicating that the operation succeeded, click Close.

Uploading the NE Data

By uploading the NE data, you can synchronize the current NE configuration data to the U2000 directly.

Prerequisites

  • The NE has been created successfully.
  • The NE software version and NMS software version are correct.
  • You are an NM user with Operator Group rights or higher.

Procedure

  1. Double-click the unconfigured NE on the Main Topology. Then, the NE Configuration Wizard dialog box is displayed.
  2. Select Upload and click Next. Then, the Confirm dialog box is displayed.
  3. Click OK to start the upload. When the uploading is completed, the Operation Result dialog box is displayed, indicating that the operation succeeded.
  4. Click Close.