Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Hotline Services

Configuring Hotline Services

This section describes how to configure hotline services. In hotline services, foreign exchange station (FXS) ports are used in pairs to transmit private telephone data.

Networking Diagram

Hotline services (block telephone services), also called driving telephone services between stations, are used for point-to-point voice communication between adjacent stations and can be connected upon off-hook without dialing.

Figure 2-25 shows the networking diagram for hotline services. Hotline services are deployed between airport terminals User A and User B. User A and User B can perform point-to-point voice communication upon off-hook without dialing to shift air traffic control. Hotline services are applicable to railway and grid networks.

Figure 2-25  Networking diagram for hotline services

NOTE:

This topic considers the OptiX OSN 580 as an example to describe the board layout. In the case of other products, the configuration method is the same, except for the slots. For the slot information, see the Hardware Description of the relevant product.

Service Planning

This section describes the parameters required for configuring hotline services.

A telephone is connected to each of NE 1 and NE 2. Each of NE 1 and NE 2 requires a 64 kbit/s service channel. Table 2-16 provides the timeslot allocation of a 64 kbit/s service channel.

Table 2-16  Timeslot allocation of a 64 kbit/s service channel
NE Board Source E1 Source Timeslot Range Sink E1 Sink Timeslot Range
NE1 5-FXSO12 DDN-1 1 2M-1(SDH_TU-65) 1
NE2 5-FXSO12 DDN-1 1 2M-1(SDH_TU-65) 1
  • The hotline services occupy the SDH_TU-65 channel during the transmission at the PCM port side.
  • The hotline services occupy the first VC-12 timeslot in the first VC-4 (VC4-1:VC12-1) on the SDH link between NE 1 and NE 2 during the transmission at the SDH network side.
Table 2-17  Port management parameters
Parameter NE1 NE2
Board 5-FXSO12 5-FXSO12
Port 5-FXSO12-1(DDN-1) 5-FXSO12-1(DDN-1)
Port Type FXS FXS
A/μ Law A law A law
Service Type Hotline service Hotline service
Other parameters Default values Default values
Table 2-18  64 kbit/s service parameters
Parameter NE1 NE2
Board 5-FXSO12 5-FXSO12
Direction Bidirectional Bidirectional
Source E1 DDN-1 DDN-1
Source Timeslot Range (e.g. 1, 3-6) 1 1
Sink E1 2M-1(SDH_TU-65) 2M-1(SDH_TU-65)
Sink Timeslot Range (e.g. 1, 3-6) 1 1
Bandwidth 1 1
Table 2-19  SDH service parameters
Parameter NE1 NE2
Level VC12 VC12
Direction Bidirectional Bidirectional
Source Slot 5-FXSO12 5-FXSO12
Source VC4 - -
Source Timeslot Range (e.g. 1, 3-6) 65 65
Sink Slot 4-SL41O-1(SDH-1) 4-SL41O-1(SDH-1)
Sink VC4 VC4-1 VC4-1
Sink Timeslot Range (e.g. 1, 3-6) 1 1

Configuration Procedure

This section describes the procedure for configuring hotline services.

Prerequisites

Procedure

  1. Configure a pulse code modulation (PCM) service on NE 1.
    1. Navigate to the NE Explore of NE1, select the desired FXSO12 board, and configure the attributes of the port for receiving and transmitting the PCM service.

      NOTE:

      In this example, retain the default values for the other parameters in the Port Management window. On live networks, set these parameters according to the network plan. For details about the parameters, see Port Management Parameters.

    2. Configure a 64 kbit/s service.

    3. Configure the cross-connection between the PCM service and an SDH link.

  2. Configure a PCM service on NE 2.

    Follow instructions in 1 to configure a PCM service on NE 2.

  3. Check whether the service is correctly configured by following instructions in Testing FXS Hotline Services.
  4. Enable the performance monitoring function for the NEs by following instructions in Enabling NE Performance Monitoring.
  5. Back up the configuration data of the NEs by following instructions in Backing Up the NE Configuration Data to the SCC Board.