Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring G.703 64 kbit/s Codirectional Services

Configuring G.703 64 kbit/s Codirectional Services

G.703 64 kbit/s codirectional services allow baseband digital signals to be directly transmitted on pulse code modulation (PCM) channels, with the goal of fully utilizing standard 64 kbit/s voice channel resources. 64 kbit/s codirectional services commonly apply to dedicated communications networks such as electricity networks and rail transport networks.

Networking Diagram

This section describes the networking of NEs.

Figure 2-35 illustrates the networking of a G.703 64 kbit/s codirectional service. With NE 1 interconnecting with one protective relay control device and NE 2 interconnecting with another protective relay control device, NE 1 and NE 2 achieve communication between the two protective relay control devices.

Figure 2-35  Networking diagram for a G.703 64 kbit/s codirectional service

NOTE:

This topic considers the OptiX OSN 580 as an example to describe the board layout. In the case of other products, the configuration method is the same, except for the slots. For the slot information, see the Hardware Description of the relevant product.

Service Flow Directions and Timeslot Allocation

A DXM12 board receives G.703 64 kbit/s codirectional services through its codirectional serial ports, aggregates and processes the G.703 64 kbit/s codirectional services, and transmits the G.703 64 kbit/s codirectional services to an SDH network. The SDH network transparently transmits the G.703 64 kbit/s codirectional services to a remote node.

Each of NE 1 and NE 2 needs one 64 kbit/s service channel. Table 2-61 lists timeslots allocated to the 64 kbit/s service channels.

Table 2-61  Timeslots allocated to the 64 kbit/s service channels
NE Board Source E1 Source Timeslot Range Sink E1 Sink Timeslot Range
NE 1 7-DXM DDN-5 1 2M-1(SDH_TU-65) 1
NE 2 7-DXM DDN-5 1 2M-1(SDH_TU-65) 1

Perform the following operations for transmission of the G.703 64 kbit/s codirectional service:

  • Allocate VC-12-1 of VC-4-1 (VC-4-1: VC-12-1) of the SDH link between NE 1 and NE 2 to transmit the codirectional service on the SDH network side.
  • Allocate channel SDH_TU-65 to transmit the codirectional service on the PDH interface side.
Table 2-62  Parameter values for the serial ports
Parameter NE 1 NE 2
Board 7-DXM 7-DXM
Port 7-DXM-5(DDN-5) 7-DXM-5(DDN-5)
Protocol Mode CO64K Mode CO64K Mode
Table 2-63  Parameter values for the 64 kbit/s service
Parameter NE 1 NE 2
Board 7-DXM 7-DXM
Board DDN-5 DDN-5
Source Timeslot Range (e.g. 1, 3-6) 1 1
Sink E1 2M-1(SDH_TU-65) 2M-1(SDH_TU-65)
Sink Timeslot Range (e.g. 1, 3-6) 1 1
Bandwidth 1 1

Configuration Procedure

This section describes the procedure for configuring a G.703 64 kbit/s codirectional service.

Prerequisites

Procedure

  1. Configure a G.703 64 kbit/s codirectional service on NE 1.
    1. Configure the port receiving the codirectional service.



    2. Configure the PDH interface.



    3. Configure a 64 kbit/s service.



    4. Configure the cross-connection from the G.703 64 kbit/s codirectional service to the SDH link.



  2. Configure a G.703 64 kbit/s codirectional service on NE 2.

    The procedure for configuring a G.703 64 kbit/s codirectional service on NE 2 is the same as that for G.703 64 kbit/s configuring a codirectional service on NE 1.

  3. Check whether the services are correctly configured by following instructions in Testing DDN Services.
  4. Enable performance monitoring on both NE 1 and NE 2. For details, see Enabling NE Performance Monitoring.
  5. Back up the configuration data of both NE 1 and NE 2. For details, see Backing Up the NE Configuration Data to the SCC Board.