OSN 500 550 580 V100R008C50 Commissioning and Configuration Guide 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Sub-rate Services

Configuring Sub-rate Services

This section describes how to configure sub-rate services. Sub-rate services are used for synchronization between narrowband devices and transmission of asynchronous data services, at a rate ranging from 2.4 kbit/s to 48 kbit/s.

Networking Diagram

This section describes the networking of NEs.

Figure 2-29 shows the networking diagram for sub-rate services. NE 1 needs to asynchronously transmit user sub-rate services (such as watt-hour meter data of each house and flying status data about airplanes) to the data center. The sub-rate services occupy a bandwidth of 9.6 kbit/s.

Figure 2-29  Networking diagram for sub-rate services

NOTE:

This topic considers the OptiX OSN 580 as an example to describe the board layout. In the case of other products, the configuration method is the same, except for the slots. For the slot information, see the Hardware Description of the relevant product.

Service Planning

This section describes the parameters required for configuring sub-rate services.

To configure sub-rate services, you need to configure the sub-rate encapsulation mode for involved NEs. Table 2-32 provides the sub-rate encapsulation mode for NE1 and NE2.

Table 2-32  Sub-rate encapsulation mode
Parameter NE1 NE2
Subrate Encaptype X.50 D3 X.50 D3

Each of NE 1 and NE 2 requires a 64 kbit/s service channel. Table 2-33 provides the timeslot allocation of a 64 kbit/s service channel.

Table 2-33  Timeslot allocation of a 64 kbit/s service channel
NE Board Source E1 Source Timeslot Range Sink E1 Sink Timeslot Range
NE1 7-DXM DDN-19 1 2M-1(SDH_TU-65) 1
NE2 7-DXM DDN-19 1 2M-1(SDH_TU-65) 1
  • The sub-rate services occupy the SDH_TU-65 channel during the transmission at the PCM port side.
  • The sub-rate services occupy the first VC-12 timeslot in the first VC-4 (VC4-1:VC12-1) on the SDH link between NE 1 and NE 2 during the transmission at the SDH network side.
Table 2-34  Parameters for serial port management
Parameter NE1 NE2
Board 7-DXM 7-DXM
Port 7-DXM-19(DDN-19) 7-DXM-19(DDN-19)
Serial Port Rate 9.6K(X.50 D3) 9.6K(X.50 D3)
Protocol Mode V.24 Mode V.24 Mode
Working Mode DCE DCE
Phase Mode Normal phase Normal phase
Synchronous NO NO
CTS/RTS Transparent Transmission Disable Disable
TX Signal (Active CTS/RTS) 0x9 0x9
TX Signal (Inactive CTS/RTS) 0xf 0xf
RX Signal (Active CTS/RTS) 0x090f 0x090f
TX Signal (Inactive CTS/RTS) 0x0f0f 0x0f0f
Other parameters Default values Default values
Table 2-35  64 kbit/s service parameters
Parameter NE1 NE2
Board 7-DXM 7-DXM
Direction Bidirectional Bidirectional
Source E1 DDN-19 DDN-19
Source Timeslot Range (e.g. 1, 3-6) 1 1
Sink E1 2M-1(SDH_TU-65) 2M-1(SDH_TU-65)
Sink Timeslot Range (e.g. 1, 3-6) 1 1
Bandwidth 1 1
Table 2-36  SDH service parameters
Parameter NE1 NE2
Level VC12 VC12
Direction Bidirectional Bidirectional
Source Slot 7-DXM 7-DXM
Source VC4 - -
Source Timeslot Range (e.g. 1, 3-6) 65 65
Sink Slot 4-SL41O-1(SDH-1) 4-SL41O-1(SDH-1)
Sink VC4 VC4-1 VC4-1
Sink Timeslot Range (e.g. 1, 3-6) 1 1

Configuration Procedure

This section describes the procedure for configuring sub-rate services.

Prerequisites

Procedure

  1. Configure a pulse code modulation (PCM) service on NE 1.
    1. Configure the port for receiving and transmitting a PCM service.

      Click Apply.

      NOTE:

      In this example, retain the default values for the other parameters on the Serial Port Management page. Plan the parameters according to the actual networking. For details about the parameters, see Parameters for Serial Port Management.

    2. Configure the attributes of the PDH port.

    3. Configure a 64 kbit/s service.

    4. Configure the cross-connection between the PCM service and an SDH link.

  2. Configure a PCM service on NE 2.

    Follow instructions in 1 to configure a PCM service on NE 2.

  3. Check whether the service is correctly configured by following instructions in Testing Sub-Rate Services.
  4. Enable the performance monitoring function for the NEs by following instructions in Enabling NE Performance Monitoring.
  5. Back up the configuration data of the NEs by following instructions in Backing Up the NE Configuration Data to the SCC Board.