OceanStor 2600 V3 Video Surveillance Edition V300R006 Basic Storage Service Configuration Guide for File

This document is applicable to OceanStor OceanStor 2600 V3 Video Surveillance Edition. This document describes the basic storage services and explains how to configure and manage basic storage services for storage system.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Modifying the Advanced Properties of a Storage Pool

Modifying the Advanced Properties of a Storage Pool

This operation enables you to modify the advanced properties of a storage pool.

Procedure

  1. Log in to DeviceManager.
  2. Choose Provisioning > Storage Pool.
  3. Select the storage pool whose properties you want to modify and click Properties.

    The Properties of Storage Pool dialog box is displayed.

  4. Click the Advanced tab.

    Table 4-4 describes the related parameters.

    Table 4-4 Storage pool advanced parameters

    Parameter

    Description

    Setting

    Used Capacity Alarm Threshold (%)

    If the storage pool contains a file system with value-added services or a thin file system, an alarm will be generated when the percentage of the storage pool's used capacity to its total capacity reaches the used capacity alarm threshold. Alarms are generated in the following circumstances:

    • When the used capacity reaches the used capacity alarm threshold, the system generates an alarm informing that the capacity of storage pool is insufficient.
    • When the used capacity alarm threshold is not greater than 88 and the used capacity reaches 90%, the system generates an alarm informing that the storage pool is running out.
    • When the used capacity alarm threshold is greater than 88 and the used capacity reaches (used capacity alarm threshold + 2) %, the system generates an alarm informing that the storage pool is running out.
    NOTE:

    If the used capacity alarm threshold is set to 85:

    • When the used capacity reaches 85%, the system generates an alarm informing that the capacity of storage pool is insufficient.
    • When the used capacity reaches 90%, the system generates an alarm informing that the storage pool is running out.

    If the used capacity alarm threshold is set to 91:

    When the used capacity reaches 93%, the system generates an alarm informing that the storage pool is running out.

    A proper used capacity alarm threshold helps you monitor the capacity usage of a storage pool.

    [Value range]

    1 to 95

    [Default Value]

    80

  5. Click OK.

    The Execution Result dialog box is displayed, indicating that the operation succeeded.

  6. Click Close.