Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Point-to-Point Transparently Transmitted E-Line Services

Configuring Point-to-Point Transparently Transmitted E-Line Services

This section uses a point-to-point transparently transmitted E-Line service as an example to describe how to configure Ethernet services according to the network plan.

Networking Diagram

As shown in Figure 2-1, the PowerCube 500 needs to transparently transmit Ethernet services from the Camera to the upper-layer network in Point-to-Point mode.

Figure 2-1 Networking diagram for transparently transmitting E-Line services in point-to-point mode

Data Preparation

The following table describes the data planned for the configuration.

Table 2-1 Data planned for the configuration

Item

Parameter

Value in This Example

Planning Guidelines

Setting the basic attributes of the ports

Port Enabled

Enabled

Set this parameter to Enabled.

Encapsulation Type

Null

Set this parameter to Null when configuring Point-to-Point Transparently Transmitted E-Line Services.

Working Mode

Auto-Negotiation

Set this parameter to the same value as that at the peer end. Typically, this parameter is set to Auto-Negotiation at the peer end.

Configuring a point-to-point transparently transmitted E-Line service

Service ID

1

Value range: 1 to 1024.

Service Name

Eline

-

Source Interface

2-EG8P-3(PORT-3)

-

Sink Interface

2-EG8P-4(PORT-4)

-

Others

Default value

-

Procedure

  1. Set the basic attributes of the ports.

  2. Configure a Point-to-Point transparently transmitted E-Line service.