Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Creating a LAG

Creating a LAG

Between two NEs, if the bandwidth and availability of the Ethernet links need to be improved, the new LAG must be created.

Prerequisites

You must be an NM user with NE operator authority or higher.

Tools, Equipment, and Materials

Web-based NMS.

Procedure

  1. Choose Configuration > Interface Management > Link Aggregation Group Management from the Function Tree.
  2. Click the Link Aggregation Group Management tab.
  3. Click New.
    The system displays the Create Link Aggregation Group dialog box.
  4. Set the LAG attributes in Attribute Settings.
  5. Set the LAG port in Port Settings.
    1. Set Main Board and Main Port.
    2. In Available Standby Ports, select Board for the standby port.
    3. In Port, select the standby port, and then click .

      NOTE:

      Hold the Ctrl key or the Shift key on the keyboard to select multiple ports.

    4. Click Apply.



Translation