Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Traffic Control of Ethernet Ports

Configuring the Traffic Control of Ethernet Ports

After traffic control is enabled, the Ethernet port sends the pause frame to instruct the peer end to stop sending Ethernet packets for a period if the link is congested, eliminating link congestion.

Prerequisites

You have logged in to the NE.

Tool

Web-based NMS (Internet Explorer 9.0 or later)

Procedure

  1. Configure the Ethernet port traffic control.

    NOTE:
    • Auto-Negotiation Flow Control Mode is valid only when Working Mode is set to Auto-Negotiation.

    • Non-Autonegotiation Flow Control Mode is valid only when Working Mode is not set to Auto-Negotiation.