Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring QinQ-based E-Line Services

Configuring QinQ-based E-Line Services

This section uses a QinQ-based E-Line service as an example to describe how to configure Ethernet services according to the service plan.

Networking Diagram

As shown in Figure 2-3, the PowerCube 500 needs to transmit service signals from the Camera to the upper-layer network based on QinQ-based E-Line services.

Figure 2-3 Networking diagram for configuring QinQ-based E-Line services

Data Preparation

The following table describes the data planned for the configuration.

Table 2-3 Data planned for the configuration
Item Parameter Value in This Example Planning Guidelines

Setting the basic attributes of the ports

Port Enabled

Enabled

Set this parameter to Enabled.

Encapsulation Type

  • 2-EG8P-3(PORT-3), which is set to Null
  • 2-EG8P-4(PORT-4), which is set to QINQ
When configuring a QinQ-based E-Line service:
  • Set this parameter to Null if the source port needs to encapsulate all packets.
  • Set this parameter to 802.1Q and specify a VLAN ID if the source port needs to encapsulate some packets.
  • Set this parameter to QINQ for QinQ links.

Working Mode

Auto-Negotiation

Set this parameter to the same value as that at the peer end. Typically, this parameter is set to Auto-Negotiation at the peer end.

Creating a QinQ link

QinQ Link ID

1

-

Port

2-EG8P-4(PORT-4)

-

S-Vlan ID

100

Value range: 1 to 4094.

Configuring a QinQ-based E-Line service

Service ID

1

Value range: 1 to 1024.

Service Name

QinQLink

-

Direction

UNI_NNI

-

Source Interface

2-EG8P-3(PORT-3)

-

QinQ Link

QinQ Link ID-1

Select the created QinQ link.

Others

Default value

-

Procedure

  1. Set the basic attributes of the ports.

  2. Create a QinQ link.

  3. Configure a QinQ-based E-Line service.