About This Document
Overview
This document describes alarms of the KunLun 9008 V5 in terms of the meaning, impact on the system, possible causes, and solutions.
Intended Audience
This document is intended for:
- Technical support engineers
- Maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows:
Symbol |
Description |
---|---|
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. |
|
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. |
|
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. |
|
Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results. NOTICE is used to address practices not related to personal injury. |
|
Calls attention to important information, best practices and tips. NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. |
Change History
Changes between document issues are cumulative. The latest document issue contains all changes made in previous issues.
Issue 11 (2021-09-24)
The issue is the eleventh official release.
Added the ALM-0x1A000043 Data Written into NAND Flash Exceeds Threshold (BMC, Minor Alarm).
Issue 10 (2021-04-29)
The issue is the tenth official release.
Modified the 0x0100002D and 0x0100006D.
Issue 09 (2021-02-20)
The issue is the ninth official release.
Added the 0x2B000003.
Issue 08 (2021-01-05)
The issue is the eighth official release.
Added the 0x0100006B and 0x0100006D.
Issue 07 (2020-09-28)
The issue is the seventh official release.
Updated the iBMC Alarm Handling to add 0x before each alarm ID and updated the ALM-0x3700001F CMC Failed to Detect BMC (SCE-LPM) Heartbeat Signals.
Issue 06 (2020-03-23)
The issue is the sixth official release.
Updated the ALM-0x12000013 Failed to Read Air Inlet Temperature (Chassis, Minor Alarm) and ALM-0x12000017 Failed to Read Outlet Temperature (Chassis, Minor Alarm).
Issue 05 (2019-05-20)
The issue is the fifth official release.
Added the 0x01000045 and 0x01000047.
Issue 04 (2019-01-07)
The issue is the fourth official release.
Added the 0x0100000D and 0x0100002D.
Issue 03 (2018-11-15)
The issue is the third official release.
Added the 0x2c000049 and 0x2c000065.
Issue 02 (2018-08-06)
The issue is the second official release.
Added the contents of 9008 V5 (with a CME).
Issue 01 (2018-06-01)
The issue is the first official release