Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2C000057 System Memory Initialization Error (System, Critical Alarm)

ALM-0x2C000057 System Memory Initialization Error (System, Critical Alarm)

Description

Alarm message:

System memory initialization error. Error code: arg1.

This alarm is generated when an error is detected during the system memory initialization. The error code is arg1.

Alarm object: system

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2C000057

Critical

No

Parameters

Name

Meaning

arg1

Error code of the alarm.

Impact on the System

The server performance is affected.

Possible Causes

  • No DIMM is installed.
  • The DIMM layout does not comply with the configuration rules.

Procedure

  1. Check whether other alarms are present.

  2. Clear other memory alarms. Then, check whether this alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Power off the server and check the DIMMs for CPU arg1 are installed.

  4. Check whether the DIMMs are installed according to the DIMM configuration guidelines.

    For details about the DIMM configuration guidelines, see the user guide of the server you use.

  5. Install the DIMMs according to the DIMM configuration guidelines. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 7.

  6. Install the DIMMs and power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 7.