Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-3300001F PIP 3 Link Fault

ALM-3300001F PIP 3 Link Fault

Description

Alarm message:

PIP 3 link fault.

Attribute

Alarm ID

Alarm Severity

Auto Clear

3300001F

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The service system may stop responding or power off, physical partition information may be messy, or the communication is abnormal between the central management enclosure (CME) and the system compute enclosure (SCE) where the local partition management module (LPM) is located.

System Actions

None

Possible Causes

  • The partition interconnect cable (PIC) is faulty.
  • The CPLD of the LPM or central partition interconnect module (CPI) is faulty.

Procedure

  1. Check whether AC power cables are connected to the SCE.

  2. Connect AC power cables to the SCE. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Check whether the PIC health indicator for the SCE is green.

  4. Replace the PIC. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 6.

  5. Replace the CPI. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 6.

  6. Contact Huawei technical support.

Clearing

After the fault is rectified, the system automatically clears the alarm.