KunLun 9008 V5 Alarm Handling 05

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x10000061 Video Controller Fault (Mainboard, Critical Alarm)

ALM-0x10000061 Video Controller Fault (Mainboard, Critical Alarm)

Description

Alarm message:

A video controller error is detected during system startup. 

This alarm is generated when the BIOS cannot detect the display device.

Alarm object: Mainboard

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x10000061

Critical

Yes

Parameters

Name

Meaning

Impact on the System

The video device connected to the server does not work.

Possible Causes

The display adapter is faulty.

Procedure

  1. Check whether the server is configured with an external display adapter.

  2. Replace the display adapter. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Getting Help.