Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x24000009 CPU Board Soft-Start Circuit Overheating (CPU Board, Major Alarm)

ALM-0x24000009 CPU Board Soft-Start Circuit Overheating (CPU Board, Major Alarm)

Description

Alarm message:

System is forcibly shut down due to high temperature of the soft-start circuit arg1.

This alarm is generated when the soft-start circuit on the CPU board exceeds 105°C. When the soft-start circuit exceeds 105°C, the CPLD protection mechanism is triggered, which forcibly shut down the server OS.

Alarm object: CPU board

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x24000009

Major

Yes

Parameters

Name

Meaning

arg1

Number of the slot, in which the compute module holding the CPU board is located.

Impact on the System

Services will be interrupted.

Possible Causes

The overcurrent protection circuit on the CPU board is faulty.

Procedure

  1. Replace the CPU board. After the server restarts, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 2

  2. Getting Help.