Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x24000007 CPU Board Clock Lost (CPU Board, Major Alarm)

ALM-0x24000007 CPU Board Clock Lost (CPU Board, Major Alarm)

Description

Alarm message:

CPU board arg1 arg2 clock signals lost.

This alarm is generated when the clock of the CPU board is lost.

Alarm object: CPU board

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x24000007

Major

Yes

Parameters

Name

Meaning

arg1

Serial number of the CPU board.

arg2

Type of the CPU board clock. For example, 100MHz.

Impact on the System

The system operation is affected.

Possible Causes

The CPU board is faulty.

Procedure

  1. Replace the CPU board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 2.