Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x49000001 BMA Failed to Create the Transfer Mapping Table (BMA, Minor Alarm)

ALM-0x49000001 BMA Failed to Create the Transfer Mapping Table (BMA, Minor Alarm)

Description

Alarm message:

iBMA failed to establish forward mapping table (arg1). 

This alarm is generated when the iBMA failed to create the transfer mapping table.

Alarm object: BMA

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x49000001

Minor

Yes

Parameters

Name

Meaning

arg1

Cause of the alarm. Example:

  • Failed to bind port 1.
  • Failed to bind port 1 and the port(s) is/are occupied.

Impact on the System

Trap messages cannot be transferred through the in-band channel.

Possible Causes

The port is in use or is not bond successfully.

Procedure

  1. Check whether the port is in use.

    • If yes, go to step 2.
    • If no, go to step 3.

  2. Use another port that is available. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 3.

  3. Check whether the virtual network port on the service side is normal. Check whether the connection status is Linkup and whether the IP address is valid.

    • If yes, go to step 5.
    • If no, go to step 4.

  4. Reset the virtual network port to ensure that the IP address is valid and the connection status is Linkup. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 5.

  5. Getting Help.