Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0000006B Failed to Read CPU Margin (CPU, Minor Alarm)

ALM-0x0000006B Failed to Read CPU Margin (CPU, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the CPU arg1 margin.

This alarm is generated when the system failed to obtain the CPU margin.

Alarm object: CPU

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0000006B

Minor

Yes

Parameters

Name

Meaning

arg1

Slot number of the CPU.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

The iBMC is abnormal.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Getting Help.