Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-36000019 Power Supply 1 Controller Fault

ALM-36000019 Power Supply 1 Controller Fault

Description

Alarm message:

Power supply 1 controller fault.

Attribute

Alarm ID

Alarm Severity

Auto Clear

36000019

Minor

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

PSU management and power management are affected.

System Actions

None

Possible Causes

  • A PSU is faulty.
  • The communications channel between the CMC and the fan module is faulty.

Procedure

  1. Check whether the PFM is operating properly.

  2. Remove and reinstall the PFM. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Replace the PFM. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Contact Huawei technical support.

Clearing

This alarm is cleared when the sensor detects that the CMC is properly communicating with the PFM.

After the fault is rectified, the system automatically clears the alarm.