Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2C000029 Forced System Power Cycle Due to Watchdog Timeout (System, Major Alarm)

ALM-0x2C000029 Forced System Power Cycle Due to Watchdog Timeout (System, Major Alarm)

Description

Alarm message:

The OS is forcibly powered off and then on due to the watchdog timeout. 

This alarm is generated when the OS is forcibly shut down and restarted as the watchdog timed out during the BIOS/power on self-test (POST), OS load, or SMS/OS start process.

NOTE:

This alarm can be generated only after the watchdog is enabled and the timeout action is set to power cycle.

Alarm object: system

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2C000029

Major

Yes

Parameters

Name

Meaning

Impact on the System

The OS shutdown and restart interrupt services running on the server.

Possible Causes

  • If the alarm is generated during the BIOS/POST process, the hardware is faulty, or a fault occurs during basic input/output system (BIOS) startup.
  • If the alarm is generated during the OS load process, a fault occurs during OS startup.
  • If the alarm is generated during the SMS/OS process, a fault occurs in the OS.

Procedure

  1. Disable the watchdog and restart the server.
  2. Use the remote keyboard, video, and mouse (KVM) to check displayed information during system startup. Determine the handling method based on the phases in which the alarm is generated.

    1. If the alarm is generated in the BIOS/POST phase, log in to the iBMC CLI, and run the ipmcget -d port80 command to check information about the port 80.
    2. If the alarm is generated in the OS Load phase, use the remote KVM to view error messages in the OS for fault locating.
    3. If the alarm is generated in the SMS/OS phase, log in to the OS, and check whether faults occur in the software where the watchdog is enabled, or the software is hung.