Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2C000043 Inconsistent PBI Boards (System, Major Alarm)

ALM-0x2C000043 Inconsistent PBI Boards (System, Major Alarm)

Description

Alarm message:

Different types of LPM boards are used.

This alarm is generated when LPMs of different models are installed in the same server.

Alarm object: system

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2C000043

Major

Yes

Parameters

Name

Meaning

Impact on the System

The system may fail to power on.

Possible Causes

  • The LPMs installed in the server are of different models.

Procedure

  1. Power off the server, and remove the power cables from the server.
  2. Check whether the models of the two LPMs are the same.

  3. Replace the improper LPM. Then power on the server and check whether the alarm is cleared.

    For details about how to replace an LPM, see the user guide of the server you use.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Getting Help.