No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

KunLun 9008 V5 Alarm Handling 05

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0100003F Failed to Read Memory Temperature (Memory, Minor Alarm)

ALM-0x0100003F Failed to Read Memory Temperature (Memory, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the memory (arg1) temperature.

This alarm is generated when the system failed to obtain the memory temperature.

Alarm object: memory

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0100003F

Minor

Yes

Parameters

Name

Meaning

arg1

  • DIMM silkscreen, for example, DIMM020 (A) or DIMM010 (B)
  • CPU socket number and channel number. For example, CPU 1 channel 2 indicates the number 2 memory channel of CPU 1, that is, DIMMs DIMM020 and DIMM021.

You can obtain the CPU socket number and channel number corresponding to a DIMM from the server user guide. See System Compute Modules > DIMM Slot Locations in the KunLun 9008 V5 User Guide.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

The iBMC does not work normally.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Getting Help.
Translation
Download
Updated: 2019-05-25

Document ID: EDOC1100023838

Views: 76116

Downloads: 16

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next