Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-33000019 Active-Standby Status Link Fault

ALM-33000019 Active-Standby Status Link Fault

Description

Alarm message:

Active-standby status link fault.

Attribute

Alarm ID

Alarm Severity

Auto Clear

33000019

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

The service system may stop responding or cannot be powered on or off, physical partition information may be messy, or the communication is abnormal between the central management enclosure (CME) and the system compute enclosure (SCE).

Possible Causes

  • The CPI is faulty or not properly installed.
  • The backplane is faulty.
  • The CMC is not properly installed.

Procedure

  1. Check whether the health indicator on the CPI is on.

  2. Replace the CPI. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  3. Remove and reinstall the CPI. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  4. Replace the backplane. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 5.

  5. Remove and reinstall the CMC. Then check whether the alarm is cleared.

    For details about how to remove and reinstall a CMC, see the KunLun 9032 V100R001 User Guide.

    • If yes, no further action is required.
    • If no, go to Step 6.

  6. Contact Huawei technical support.

Clearing

After the fault is rectified, the system automatically clears the alarm.