Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-37000043 System Product Model Does Not Match Hardware Configuration

ALM-37000043 System Product Model Does Not Match Hardware Configuration

Description

Alarm message:

The system product model does not match the current configuration.
NOTE:

This alarm is generated when the system detects that the product model does not match the hardware configuration after the server is powered on.

Attribute

Alarm ID

Alarm Severity

Auto Clear

37000043

Major

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

  • Physical partitions that match the hardware configuration cannot be created.

Possible Causes

  • The hardware configuration is changed, but the product model is not switched accordingly.

Procedure

  1. Log in to the CMC WebUI as an administrator and check whether the product model is switched.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Make sure that the conditions for product model switching are met based on the displayed message, log in to the CMC WebUI again to switch the product model, and check whether the product model is switched successfully.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Contact Huawei technical support.

Clearing

After the fault is rectified, the system automatically clears the alarm.