Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x11000005 LCD Fault (LCD, Minor Alarm)

ALM-0x11000005 LCD Fault (LCD, Minor Alarm)

Description

Alarm message:

LCD fault, or LCD-iBMC communication failure. 

This alarm is generated when the LCD is faulty or the communication between the LCD and iBMC is abnormal.

Alarm object: LCD

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x11000005

Minor

Yes

Parameters

Name

Meaning

Impact on the System

The LCD cannot be used.

Possible Causes

  • The serial cable to the LCD is faulty.
  • The LCD is faulty.

Procedure

  1. Remove and reconnect the LCD cable. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Replace the LCD cable. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Replace the LCD. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Getting Help.