Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x03000013 Communication with PSU Failed (PSU, Minor Alarm)

ALM-0x03000013 Communication with PSU Failed (PSU, Minor Alarm)

Description

Alarm message:

iBMC cannot communicate with PSU arg1.

This alarm is generated when the iBMC failed to communicate with a PSU.

Alarm object: PSU

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x03000013

Minor

Yes

Parameters

Name

Meaning

arg1

Serial number of the PSU.

Impact on the System

The PSU cannot be managed.

Possible Causes

The PSU is faulty.

Procedure

  1. Remove and reinstall the PSU. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Replace the PSU. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Getting Help.