No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

KunLun 9008 V5 Alarm Handling 05

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x29000017 Optical Module Power Abnormal (Port, Major Alarm)

ALM-0x29000017 Optical Module Power Abnormal (Port, Major Alarm)

Description

Alarm message:

Abnormal Rx or Tx powers were detected on [arg2] arg3 on arg1.

This alarm is generated when abnormal receive or transmit power was detected on the optical module.

Alarm object: port

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x29000017

Major

Yes

Parameters

Name

Meaning

arg1

NIC name, for example, NIC 1, PCIe Card 5, or LOM.

arg2

Type of the NIC, for example, (NIC) or (FC).

arg3

Network port number, for example, port 1.

Impact on the System

Data transmission over the network port will be affected. If this alarm is not cleared in a timely manner, services related to the port will be interrupted.

Possible Causes

The voltage of the optical module connected to the NIC is high.

Procedure

  1. Replace the optical module. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to step 2.

  2. Getting Help.
Translation
Download
Updated: 2019-05-25

Document ID: EDOC1100023838

Views: 102911

Downloads: 17

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next