KunLun 9008 V5 Alarm Handling 05

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-1700003F CMC External Network Communication Failed

ALM-1700003F CMC External Network Communication Failed

Description

Alarm message:

CMC external network communication failed.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1700003F

Minor

Yes

Parameters

Name

Meaning

Alarm Severity

Indicates the alarm severity.

Alarm Source

Indicates the alarm source.

Subject

Indicates the event body for which an alarm is generated.

Time

Indicates the time when an alarm is generated.

Description

Provides an alarm description.

Event Code

Indicates the event code of an alarm.

Impact on the System

If this alarm occurs on the active CMC, you cannot access the active CMC from the external network.

System Actions

None

Possible Causes

  • The configuration data is incorrect.
  • The network cable is faulty.
  • The board is faulty.

Procedure

  1. Check whether the network cable is properly connected.

  2. Remove and reconnect the network cable. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Check whether the network configurations of the CMC and the client are correct.

  4. Modify the network configurations of the CMC and the client. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 5.

  5. Contact Huawei technical support.

Clearing

This alarm is cleared when the sensor detects that the data configuration of the management network port is correct.

After the fault is rectified, the system automatically clears the alarm.